FilterITU Grid 100 GHz≤300 mW

Polarization-Maintaining Dense Wavelength Division Multiplexer (1×2-10G)
The PM Dense Wavelength Division Multiplexer supports ITU Grid 100GHz channel spacing and is available in 100G and 200G port configurations. Passband insertion loss ≤1.2dB,, bandwidth @0.5dB, typical isolation ≥0.2nm,, high extinction ratio (≥18dB),), high directivity (≥45dB),), high return loss (≥50dB),), low ripple (≤0.3dB).). Center wavelength stability ≤0.002nm,, thermal stability ≤0.005dB/°C. Compliant with Telcordia GR-1209-CORE and GR-1221-CORE standards; RoHS certified. Features PM Panda fiber, max power 300mW,, operating temperature -5~+70°C, package size Φ5.5×34/35/38mm. Widely used in DWDM networks, optical amplifiers, and CATV fiber optic systems.
100G Bandwidth
Port Type1×2
Channel SpacingITU Grid 100 GHz
Central wavelengthITU Grid
Passband Insertion Loss (CWL ±0.11nm))≤1.2dB
Passband bandwidth @ 0.5dB≥0.2(0.4) nm
Passband bandwidth @25dB≤1.4nm
Typical Isolation in Passband30dB
In-band isolation≥25dB
Typical insertion loss of reflective strip0.3dB
Reflective insertion loss≤0.5dB
Typical Isolation of Reflective Strip15dB
Reflective band isolation≥12dB
Ripple≤0.3dB
Extinction Ratio≥18dB
Directional≥45dB
Return Loss≥50dB
Center wavelength stability≤0.002nm
Thermal stability≤0.005dB/℃
Maximum Optical Power≤300 mW
Maximum Tensile Load≤5N
Fiber TypePM 1550 Panda Fiber
Operating Temperature-5~+70℃
Storage Temperature-40~+85℃
Available Options
Key Features
- Low Insertion Loss
- High Isolation
- High extinction ratio
- High Directionality
- Excellent center wavelength stability
Specifications
100G Bandwidth
| Parameter | Value |
|---|---|
| Port Type | 1×2 |
| Channel Spacing | ITU Grid 100 GHz |
| Central wavelength | ITU Grid |
| Passband Insertion Loss (CWL ±0.11nm)) | ≤1.2dB |
| Passband bandwidth @ 0.5dB | ≥0.2(0.4) nm |
| Passband bandwidth @25dB | ≤1.4nm |
| Typical Isolation in Passband | 30dB |
| In-band isolation | ≥25dB |
| Typical insertion loss of reflective strip | 0.3dB |
| Reflective insertion loss | ≤0.5dB |
| Typical Isolation of Reflective Strip | 15dB |
| Reflective band isolation | ≥12dB |
| Ripple | ≤0.3dB |
| Extinction Ratio | ≥18dB |
| Directional | ≥45dB |
| Return Loss | ≥50dB |
| Center wavelength stability | ≤0.002nm |
| Thermal stability | ≤0.005dB/℃ |
| Maximum Optical Power | ≤30 mW |
| Maximum Tensile Load | ≤5N |
| Fiber Type | PM 1550 Panda Fiber |
| Operating Temperature | -5~+70℃ |
| Storage Temperature | -40~+85℃ |
200G Bandwidth
| Parameter | Value |
|---|---|
| Port Type | 1×2 |
| Channel Spacing | ITU Grid 200 GHz |
| Central wavelength | ITU Grid |
| Passband Insertion Loss (CWL ±0.11nm)) | ≤1.2dB |
| Passband bandwidth @ 0.5dB | ≥0.2(0.4) nm |
| Passband bandwidth @25dB | ≤1.4nm |
| Typical Isolation in Passband | 30dB |
| In-band isolation | ≥25dB |
| Typical insertion loss of reflective strip | 0.3dB |
| Reflective insertion loss | ≤0.5dB |
| Typical Isolation of Reflective Strip | 15dB |
| Reflective band isolation | ≥12dB |
| Ripple | ≤0.3dB |
| Extinction Ratio | ≥18dB |
| Directional | ≥45dB |
| Return Loss | ≥50dB |
| Center wavelength stability | ≤0.002nm |
| Thermal stability | ≤0.005dB/℃ |
| Maximum Optical Power | ≤30 mW |
| Maximum Tensile Load | ≤5N |
| Fiber Type | PM 1550 Panda Fiber |
| Operating Temperature | -5~+70℃ |
| Storage Temperature | -40~+85℃ |